For loading and unloading of tankers and barges with cryogenic gases as oxygen,
nitrogen, acetylen, carbon dioxide, LPG, ammonia, etc. Specialy designed for offshore loading of LPG tankers. Exceed IMO and Gas Carrier Codes.
|
Technical data
| Construction | Innex helix SS 316; Outer helix SS 316; Inner leyer Polyamyde; Leyers Polyamide/Polyester; Outer leyer Polyamyde |
| Tº range | -200 °C ÷ +80 °C |
| Suction | 0,8 bar |
| Tests | Hoses assemblies are tested to a minimum 15 times their maximum working pressure before dispatch and issued with test certificates. All hoses have a safety factor of 5 on working pressure. CRIOGEN hoses for marine applications has been independently tester by Lloyds as comformint to BS 4089:1989 and to IMO GAS carrier Code requirements. Hoses for ammonia cervices are identified with a yellow stripe |
| Sertification | For each hose |
| Applicable standarts | BS EN 13766 International Maritime Organization IGC Code (for marine application) Unated States Coastguard Requirements (for marine application) |
Number |
ID |
OD |
WP |
BP |
Wieght |
R min |
CRIO25 |
25 |
- |
25 |
125 |
1 |
100 |
CRIO38 |
38 |
- |
25 |
125 |
1,5 |
140 |
CRIO50 |
50 |
- |
25 |
125 |
2,5 |
180 |
CRIO65 |
65 |
- |
25 |
125 |
3,3 |
205 |
CRIO75 |
75 |
- |
25 |
125 |
4,5 |
280 |
CRIO100 |
100 |
- |
25 |
125 |
7,5 |
295 |
CRIO150 |
150 |
- |
21 |
105 |
13,5 |
510 |
CRIO200 |
200 |
- |
21 |
105 |
18,5 |
760 |
CRIO250 |
250 |
- |
15 |
75 |
25,0 |
915 |
Vidi više | ||||
|